MTG2 Material Thickness Gauge

With automatic transducer recognition which ensures  correct probe identification even when the transducer is changed, a measurement rate of 4Hz (4 readings per second) and integral zero disc ensuring maximum accuracy of ±1%, the MTG2 is ideal for taking basic ultrasonic thickness measurements.

The MTG2 is supplied complete with 5MHz, ¼” transducer and is pre-calibrated for measuring on steel only with a thickness range of up to 500mm (20”) in Pulsed-Echo (P-E) mode.

Compatible with ElcoMaster® software, individual readings can be downloaded via USB to PC or similar device for further analysis.

 

MTG2 Material Thickness Gauge 

Features:

  • Pulsed-Echo (P-E) measurement Mode
  • Pre-calibrated for measuring on steel only
  • Pre-set measurement rate of 4 readings per second
  • USB data output to PC or similar device

 

Select a transducer

 

Pulsed Echo (P-E) Measurement Mode Measurement Rate of 4Hz

MTG2 Material Thickness Gauge
MTG2 Material Thickness GaugeMTG2 Material Thickness GaugeMTG2 Material Thickness Gauge

Technical Specification

Product Features

Part Number (with Transducer)1

MTG2-TXC

Easy to use menu structure in multiple languages

Tough, impact, waterproof and dust resistant equivalent to IP54

Bright colour screen with permanent backlight

Ambient light sensor, with adjustable brightness

Scratch and solvent resistant display; 2.4" (6cm) TFT

Large positive feedback buttons

USB power supply via PC

Gauge software updates2 via ElcoMaster® Software

2 year gauge warranty3   

Measurement Rate

4Hz
Measurement Mode Range4 Accuracy5    ■  

Pulsed Echo (P-E)

0.63-500mm ±0.1mm (0.63-19.99mm) ± 0.004" (0.025-0.787")
(0.025-20") ±0.5% (20.00-500.00mm) ±0.5% (0.788-20.00")

Measurement Units

mm or inches

Repeatability / Stability Indicator

Display Mode

Reading

Selectable Reading Resolution

Lo; 0.1mm, 0.01 Inch, 10m/s, or 0.001 in/μs

Calibration Options

Zero (using the integral zero disc)

Data Output

USB to PC

Transducer Probe Type 

Dual Element

Auto transducer recognition   
Auto V-path correction   

Battery Type6

2 x AA

Battery Life6

Alkaline : 15 hours
Lithium: 28 hours

Operating Temperature

-10 to 50°C (14 to 122°F)

Size (w x h x d)

145 x 73 x 37mm (5.7 x 2.84 x 1.46")

Gauge Weight (including batteries)

210g (7.4oz)

Packing List  

Elcometer MTG2 Ultrasonic Material Thickness Gauge, 5MHz ¼” right angle dual element
transducer, ultrasonic couplant, carry pouch, screen protector, wrist harness, 2 x AA batteries,
operating instructions, calibration certificate & 2 year warranty extension card



STANDARDS

ASTM E797, EN 14127, EN15317

 

1 5MHz 1/4" right angle transducer supplied
2 Internet connection required
3 The Elcometer MTG range is extendable within 60 days from date of purchase, free of charge to two years
4 Dependent on the material being measured and the transducer being used
5 On steel
6 Approximate battery life, when in Continuous Reading Mode at a reading rate of 4Hz. Rechargeable batteries may differ. 

Transducers

 

MTG Transducers

 

The MTG Transducer range has intelligent automatic transducer recognition ensuring correct probe identification even when the transducer is changed.

MTG Transducer

 

 

 

 

 

Suitable for measuring

Part Number

Probe

Diameter

Probe

Characteristic

Damping

Thin

Plastics

Steel

Glass

5.00 MHz Dual Element Thickness Transducer

TXC5M00CP-4

1/4"

Right Angle

S

 

All transducers are supplied with a calibration certificate. 

Accessories

Calibration Standard Sets

Part Number Description 

T920CALSTD-SET1

Calibration Standard Set;
Nominal Thickness; 2-30mm (0.08-1.18")1
Comprising of nominal thickness; 2, 5, 10, 15, 20, 25 & 30mm (0.08, 0.20, 0.39, 0.59, 0.79, 0.98 & 1.18"), complete with holder and calibration certificate. 

T920CALSTD-SET2

Calibration Standard Set;
Nominal Thickness; 40 - 100mm (1.57 - 3.94")1
Comprising of nominal thickness; 40, 50, 60, 70, 80, 90 & 100mm (1.57, 1.97, 2.36, 2.76, 3.15, 3.54 & 3.94"), complete with holder and calibration certificate 

T920CALSTD-HLD

Calibration Holder;

for thicknesses up to 100mm (3.94")

     

Individual Calibration Standards

Part Number

Nominal Thickness (mm)

Nominal Thickness (inches)1

T920CALSTD-2

2 0.078

T920CALSTD-5

5 0.196

T920CALSTD-10

10 0.393

T920CALSTD-15

15 0.590

T920CALSTD-20

20 0.787

T920CALSTD-25

25

0.984

T920CALSTD-30

30 1.181

T920CALSTD-40

40 1.574

T920CALSTD-50

50

1.966

T920CALSTD-60

60

2.362

T920CALSTD-70

70

2.755

T920CALSTD-80

80

3.149

T920CALSTD-90

90

3.543

T920CALSTD-100

100 3.937

 

   

Ultrasonic Couplant

T92015701

Ultrasonic Couplant; 120ml (4fl oz)

T92015701-5

Ultrasonic Couplant; 120ml (4fl oz), Pack of 5 Bottles

T92024034-7

Ultrasonic Couplant; 300ml (10fl oz)

T92024034-8

Ultrasonic Couplant; 500ml (17fl oz)

T92024034-3

Ultrasonic Couplant; 3.8l (1 US Gallon)

T92024034-9

High Temperature Couplant 371°C (700°F); 60ml (2fl oz)

T92024034-10

High Temperature Couplant 371°C (700°F); 60ml (2fl oz), Pack of 2

 

 

 

Transducer Adaptor

 

These adaptors allow single & dual element, 'non-intelligent' and other transducers with lemoconnectors from Elcometer NDT and other manufacturers, to be used with the MTG & PTG product range.

Part Number

Description

T92024911 Dual Element2

Transducer Adaptor

 

1 Imperial values for information purposes only. Calibration standards are manufactured and measured in millimeters.

2 This adaptor allows dual element, 'non-intelligent' and other transducers with Lemo Connectors from Elcometer and other manufacturers to be used with the MTG product range.

Videos

Material Thickness Gauge

An Introduction to Ultrasonic NDT using the Elcometer MTG2 Material Thickness Gauge

The Elcometer MTG2 Ultrasonic Material Thickness Gauge has been designed to provide fast, accurate material thickness measurements of uncoated steel substrates - ideal for monitoring corrosion and erosion before painting.

 

Click here to download the video script in English.

RELATED VIDEOS

<P>An Introduction to Ultrasonic NDT using the Elcometer MTG2 Material Thickness Gauge</P>
Material Thickness Gauge

An Introduction to Ultrasonic NDT using the Elcometer MTG2 Material Thickness Gauge

The Elcometer MTG2 Ultrasonic Material Thickness Gauge has been designed to provide fast, accurate material thickness measurements of uncoated steel substrates - ideal for monitoring corrosion and erosion before painting.

 

Click here to download the video script in English.
https://www.youtube.com/embed/GoNdEqLWK0M?rel=0
How to measure material thickness using the Elcometer MTG8 Ultrasonic Thickness Gauge
Material Thickness
How to measure material thickness using the Elcometer MTG8 Ultrasonic Thickness Gauge

Capable of measuring almost any coated or uncoated material, for a wide range of applications – including steel pipelines and storage tanks, porcelain basins, plastic piping, or rubber linings


Click here to download the video script in English.

https://www.youtube.com/embed/ylIUOz-2284
How do Ultrasonic NDT Thickness Gauges work?
Material Thickness
How do Ultrasonic NDT Thickness Gauges work?

Ultrasonic NDT gauges such as the Elcometer MTG Material Thickness Gauges, and the Elcometer PTG Precision Thickness Gauges; are designed to provide accurate, reliable material thickness measurements for a wide range of applications - including pipelines, storage tanks, rubber linings or thin plastic bottles for example.


Click here to download the video script in English.

https://www.youtube.com/embed/38W5RVqK9ZA