The multi-point conductivity sensors enable the Elcometer 130 SSP to accurately display salt concentration, showing exactly where the contamination lies and generating full colour salt density maps in 2D or 3D.
“Four Bresle equivalent readings in 2½ minutes”
Each filter paper is the size of four Bresle patches - the Elcometer 130 Soluble Salt Profiler not only displays the individual reading, but also provides four Bresle equivalent readings in just over two minutes.
View the Elcometer 130 SSP Bresle Patch Equivalence report.
“The new Elcometer 130 SSP doesn’t just measure the level of soluble salts”
In addition to soluble salt levels (cleanliness) or conductivity, the Elcometer 130 SSP carries out a detailed analysis of the test area - providing an accurate salt density profile map, pinpointing areas of high contamination outside user defined limits.
“Accurate in all environments”
This new, easy to use, Elcometer 130 SSP has automatic temperature compensation ensuring accuracy in all climatic conditions. Impure water can be offset for accurate and repeatable readings.
“Each gauge is designed to last”
Robust, durable & water resistant, the new Elcometer 130 SSP is available with a 2 year manufacturer’s warranty; giving you peace of mind.
“Generate instant reports on your PC, Android™ or iOS mobile devices”
The Elcometer 130 SSP wirelessly transmits readings, statistics and batches via Bluetooth® or via USB straight into an inspection application or into ElcoMaster®, Elcometer’s Mobile App, for instant report generation at your desk or, using your mobile, in the field.
What you do with the collected data is just as important as taking the readings themselves.
“Calibration verification - peace of mind”
A Calibration Verification Tile is available for verifying the accuracy of the gauge whilst out in the field and the verification date is recorded for use in reports.
Calibration Verification Tile available for verifying the accuracy of the gauge. Click on the Accessories tab to find out more.
Key features of the Elcometer 130 Soluble Salt Profiler include:
Display Modes
Large Single Reading
The reading value is displayed for the whole sample.
Four Bresle Patch Equivalent Readings
The measurement area is split into four Bresle Patch size quadrants and four Bresle Patch or Elcometer 130 equivalent readings are displayed simultaneously.
Provides a visual indication of salt contamination. Areas where soluble salts levels are above the limit set are shaded red, areas below the limit are white. The measurement bar to the left of the pass/fail map displays the limit (above the bar) and the percentage test area above the defined limit (below the bar). The bar is also a visual indication of the pass/fail percentage. The highest (Hi), lowest (Lo) and average (X) reading for the current measurement are displayed to the right.
2D Salt Density Map with High/Low Readings
Levels of soluble salts are illustrated using a green and red contour system; green for very low salt concentration or uncontaminated areas; yellow for areas with mid salt concentration; and red for areas with levels of salt contamination exceeding the defined map scale range.
3D Salt Density Profile & Peak Salt Concentration (Hi)
Provides a visual indication of the density of salt contamination over the test area.
How to use the Elcometer 130 Soluble Salt Profiler
![]() |
![]() |
![]() |
1. Wearing clean disposable gloves (supplied), fill a syringe with precisely 1.6ml of pure distilled water. |
2. Using tweezers, remove a filter paper from the pack and place it on the cleaned, non-labelled side of the magnetic disc supplied. |
3. Disperse the water from the syringe, evenly across the whole of the filter paper and remove any bubbles from under the paper. |
|
|
|
![]() |
![]() |
![]() |
4. Place the magnetic disc, with wetted paper face down on to the area under test, pressing firmly into any contours or irregularities and start the 2 minute timer on the gauge. |
5. After two minutes, carefully remove the filter paper and magnetic disc from the test surface and place on to the measurement electrodes. |
6. As each filter paper remains on the surface for two minutes, multiple tests can be undertaken at the same time, reducing inspection times further. |
|
|
|
![]() |
![]() |
|
7. Close the lid, ensuring that the magnetic catch is fully engaged, the gauge will begin measuring. |
8. The reading will be displayed on screen in the chosen display mode. |
9. Place the filter paper in a resealable bag (supplied), if required for further analysis. |
Elcometer 130 SSP: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (5th generation).
“Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.
iPad, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a trademark of Apple Inc., registered in the U.S. and other countries. Suitable for mobile devices running Android™ software version 2.1 and upwards. Android™ and Google Play are trademarks of Google Inc.
|
| ||
Product Features | |||
Model SSP | |||
Repeatable & reproducible measurements |
■ | ||
Easy to use menu structure; in 30+ languages |
■ | ||
Tough, impact, waterproof & dust resistant; equivalent to IP64 |
■ | ||
Bright colour screen; with permanent back light |
■ | ||
Scratch & solvent resistant display; 2.4” (6cm) TFT |
■ | ||
2 year gauge warranty* |
■ | ||
USB power supply; via PC |
■ | ||
Calibration certificate |
■ | ||
Calibration verification mode (with optional certified calibration tile) |
■ | ||
Ambient light sensor; with adjustable auto brightness |
■ | ||
Emergency light mode |
■ | ||
Magnetic & tripod mounting points |
■ | ||
Data output, USB to PC & Bluetooth to PC, Android™ & iOSǂ devices |
■ | ||
On screen statistics |
|||
Number of readings (n); Mean/ Average, (x); Standard deviation (σ); Highest reading/ Peak Salt Concentration (Hi;) Number of readings above high limit |
■ | ||
Gauge memory |
|||
Number of individual reading sets; including salt density, pass/fail map & distribution graph |
|
|
3,500 |
Number of batches |
|
|
1,000 |
Measurement units & range |
|||
Surface Cleanliness - Elcometer 130 Mode |
|
|
0-50µg/cm² (0-500mg/m²) |
Surface Cleanliness - Bresle Equivalent Method Mode |
|
|
0-15µg/cm² (0-150mg/m²) |
Conductivity |
|
|
0-6000µS/cm (0-6mS/cm) |
Resolution |
|||
Surface Cleanliness |
|
|
0.1μg/cm² (1mg/m²) |
Conductivity |
|
|
1µS/cm (0.001mS/cm) |
Gauge Accuracy |
|
|
±1% of reading |
Measurement mode |
|||
Surface Cleanliness |
■ | ||
Conductivity |
■ | ||
Calibration offset mode |
■ | ||
Automatic temperature compensation |
■ | ||
ElcoMaster® software & USB cable |
■ | ||
Individual reading and profile map stored with time and date |
■ | ||
Plastic transit case |
■ | ||
Alpha-numeric batch names; user definable on the gauge |
■ | ||
Fixed batch size mode; with batch linking |
■ | ||
Delete last reading |
■ | ||
Limits; (gauge & batch specific) |
■ | ||
Review, copy, clear & delete batches & calibration settings |
■ | ||
Trend graph; last 20 readings |
■ | ||
Batch review graph |
■ | ||
Analogue bar graph |
■ | ||
Technical Specification | |||
Model |
Description |
Certificate | |
E130-SP |
Elcometer 130 Soluble Salt Profiler |
||
E130-SPC |
Elcometer 130 Certified Soluble Salt Profiler |
• | |
Operating Range |
5°C - 40°C (41°F - 104°F) | ||
Power Supply |
4 x AA batteries or via USB (rechargeable batteries can also be used) | ||
Battery Life |
Alkaline: Approximately 30 hours Lithium: Approximately 45 hours | ||
Sample Time |
2 minutes | ||
Sampling Size |
110mm (4.3") circle | ||
Dimensions |
250 x 145 x 50mm (9.8 x 5.7 x 1.9") | ||
Weight |
780g (1.72lb) | ||
Packing List |
Elcometer 130 Soluble Salt Profiler, 3 x magnetic discs, 100 x high purity test papers, 250ml (8.5fl oz) pure distilled water, 20 x PVC storage bags, disposable gloves, sensor wipes, 3 x 3.0ml (0.1fl oz) syringes, 2 x plastic tweezers, 4 x AA batteries, shoulder strap, plastic transit case, test certificate and operating instructions, USB cable, ElcoMaster® software |
STANDARDS:
NSI 009-32, SSPC Guide 15, Bresle Equivalent ISO 8502-9 Test Method
* The Elcometer 130 SSP is supplied with a one year warranty against manufacturing defects. Gauge warranty can be extended to two years here.
ǂ Click here to find out how to integrate Elcometer’s MFi certified products to your App.
• Calibration certificate supplied as standard
|
|
|
Certificate |
|
T13027115 |
Calibration Verification Tile |
● |
|
T13025964 |
Magnetic Discs (x3) |
|
|
T13024091 |
3.0ml / 0.1fl oz Syringe (x3) |
|
|
T13024093 |
Self Seal Polythene Bags (x20) |
|
|
T99911344 |
Pure Distilled Water - 250ml (8.5fl oz) Bottle with 3ml syringe |
|
![]() |
T13027596 |
Pure Distilled Water - 1000ml (33.8fl oz) Bottle with 3ml syringe |
|
|
T13024094 |
High Purity Test Papers (x100) |
|
|
T13024092 |
Disposable Vinyl Gloves (x20) |
|
|
T13024098 |
Plastic Tweezers (x2) |
|
![]() |
T13024087 | Box of 72 Sensor Wipes | |
![]() |
T99920130 | USB Bluetooth® Adaptor V2.1+ |
Explore key features and benefits of the new Elcometer 130 Soluble Salt Profiler. See the Elcometer 130 produce Bresle equivalent readings in just over two minutes. View a wide range of display modes including 2D and 3D salt density profile maps.
Click here to download the video script in English.
Explore key features and benefits of the new Elcometer 130 Soluble Salt Profiler. See the Elcometer 130 produce Bresle equivalent readings in just over two minutes. View a wide range of display modes including 2D and 3D salt density profile maps.
Click here to download the video script in English.
By using the Elcometer 130’s Calibration Verification Tiles, you can quickly verify the accuracy of your Elcometer 130 anytime and anywhere. The Elcometer Calibration Verification Tiles are used to check each gauge’s measurement electrodes by accurately simulating known salt concentrations.
Click here to download the video script in English.