Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester

  • Industrial Finishing
6910-Setaflash-Series-8-Active-Cool

The Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester offers the same features as the Setaflash ‘Series 8’ Closed Cup Tester but is designed with a temperature range of -30°C to 135°C (-22°F to 275°F) with no external cooling required.

  • Summary
    • Summary

    • This Active Cool Closed Cup Tester uses the Peltier cell technology for heating and cooling, ensuring precise temperature control and rapid cool down after a test is completed.

      When connected to a suitable water supply, the temperature range is extended down to -20°C (- 4°F) and operates with an electric ignition.

      • Small sample size, 2ml (0.067fl oz) or 4ml (0.135fl oz)
      • Flash/No Flash & Ramp Modes
      • Electric ignitor
      • Automatic dipping and flash detection
      • Active-Cool electronic Peltier cooling
      • 64 test memory & USB port
  • Technical Information
    • Technical Specification
      Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
      Part Number Description Certificate
      K6910M021 Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
      Calibration Certificate supplied as standard
      Temperature Range -30°C to 135°C (-22°F to 275°F)
      Sample Size 2ml (0.067fl oz) or 4ml (0.135fl oz) according to method
      Test Modes Rapid Equilibrium and Ramp
      Test Duration Rapid Equilibrium Mode 1 minute below 100°C (212°F), 2 minutes above 100°C (212°F), FAME 1 minute or user defined 1 to 99 minutes
      Test Duration Ramp Mode Typically 7 minutes
      Cool Down Time 80°C to 20°C (176°F to 68°F) in 4 minutes
      Cup Material Aluminium
      Dimensions 300 x 340 x 380mm (11.8 x 13.4 x 15.0”)
      Weight 8kg (17.6lb)
      Packing List Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester, 2ml (0.067fl oz) syringe, ignitor, mains power cable, programming plug, 2mm Allen key, 2.5mm Allen key, certified flash point material (50ml/1.7fl oz), certificate of calibration, warranty registration form and operating instructions
      Calibration Certificate supplied as standard.
  • Standards
    • Standards
      Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester

      ASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS 2000-523, CLP Regulations EC No 1272/2008, EPA 1020 A & B, ISO 3679, ISO 3680, UN Class 3 Non-viscous Flammable Liquids

      Standards in grey have been superseded but are still recognised in some industries.

  • Downloads
    • Downloads
        • Elcometer 6910 Setaflash 'Series 8' Datasheet

  • Part Numbers
    • Part Numbers
      Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
      • Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
        • Part Number : K6910M021
  • Accessories
    • Accessories
      Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
      • Part Number: KT006910N009

Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester

  • Industrial Finishing
6910-Setaflash-Series-8-Active-Cool

The Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester offers the same features as the Setaflash ‘Series 8’ Closed Cup Tester but is designed with a temperature range of -30°C to 135°C (-22°F to 275°F) with no external cooling required.

Summary

Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester

This Active Cool Closed Cup Tester uses the Peltier cell technology for heating and cooling, ensuring precise temperature control and rapid cool down after a test is completed.

When connected to a suitable water supply, the temperature range is extended down to -20°C (- 4°F) and operates with an electric ignition.

  • Small sample size, 2ml (0.067fl oz) or 4ml (0.135fl oz)
  • Flash/No Flash & Ramp Modes
  • Electric ignitor
  • Automatic dipping and flash detection
  • Active-Cool electronic Peltier cooling
  • 64 test memory & USB port
Downloads
    • Elcometer 6910 Setaflash 'Series 8' Datasheet

Technical Specification
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
Part Number Description Certificate
K6910M021 Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
Calibration Certificate supplied as standard
Temperature Range -30°C to 135°C (-22°F to 275°F)
Sample Size 2ml (0.067fl oz) or 4ml (0.135fl oz) according to method
Test Modes Rapid Equilibrium and Ramp
Test Duration Rapid Equilibrium Mode 1 minute below 100°C (212°F), 2 minutes above 100°C (212°F), FAME 1 minute or user defined 1 to 99 minutes
Test Duration Ramp Mode Typically 7 minutes
Cool Down Time 80°C to 20°C (176°F to 68°F) in 4 minutes
Cup Material Aluminium
Dimensions 300 x 340 x 380mm (11.8 x 13.4 x 15.0”)
Weight 8kg (17.6lb)
Packing List Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester, 2ml (0.067fl oz) syringe, ignitor, mains power cable, programming plug, 2mm Allen key, 2.5mm Allen key, certified flash point material (50ml/1.7fl oz), certificate of calibration, warranty registration form and operating instructions
Calibration Certificate supplied as standard.
Standards
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester

ASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS 2000-523, CLP Regulations EC No 1272/2008, EPA 1020 A & B, ISO 3679, ISO 3680, UN Class 3 Non-viscous Flammable Liquids

Standards in grey have been superseded but are still recognised in some industries.

Part Numbers
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
  • Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
    • Part Number : K6910M021
   
Accessories
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
  • Part Number: KT006910N009