elcometer.com Elcometer 115 Wet Film Combs


Elcometer 115 Wet Film Combs

Bookmark and Share

Product Description


These reusable precision stainless steel combs are made to be long lasting and are supplied with either Metric or Imperial measurements.

Four separate thickness ranges are available up to a maximum of 1270µm / 50mils and are manufactured to an accuracy of 5% or 2.5µm (0.01mil), whichever is the greater.

Each comb has 10 measurement steps (teeth).

Using a wet film comb

Place a comb perpendicular to and touching the substrate. Hold the comb in position and wait a few seconds until the teeth are wet. Remove the comb from the film.  The wet film thickness lies between the biggest value ‘coated’ or ‘wet’ tooth and the smallest value ‘uncoated’ or ‘dry’ tooth.



using a comb

Elcometer 115 Wet Film Combs
Elcometer 115 Wet Film Combs
Elcometer 115 Wet Film Combs

Technical Specification

METRIC COMBS 
Part Number Range
Measurement Steps
B11529455M 20 – 325µm 20, 35, 50, 75, 100, 125, 175, 225, 375, 325µm
B11529456M 50 – 450µm 50, 75, 100, 150, 200, 250, 300, 350, 400, 450µm
B11529457M

50 – 750µm

50, 100, 150, 200, 250, 350, 450, 550, 650, 750µm

B11529458M

125 – 1250µm

125, 250, 375, 500, 625, 750, 875, 1000, 1125, 1250µm

B1152959WM

-

Set of 4 Wet Film Combs

Certificate available Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability.
Accredited Certificate: can be issued for Fixed Calibration Equipment and a full UKAS traceable certificate is issued from an independent Calibration Laboratory.

 

IMPERIAL COMBS 
Part Number Range
Measurement Steps
B11529451E 1 – 13mils 1, 1.5, 2, 3, 4, 5, 7, 9, 11, 13mils
B11529452E 2 – 18mils 2, 3, 4, 6, 8, 10, 12, 14, 16, 18mils
B11529453E

2 – 30mils

2, 4, 6, 8, 10†, 10†, 15, 20, 25, 30mils

B11529454E

5 – 50mils

5, 10, 15, 20, 25, 30, 35, 40, 45, 50mils

B1152959WE

-

Set of 4 Wet Film Combs

Certificate available Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability.
Accredited Certificate: can be issued for Fixed Calibration Equipment and a full UKAS traceable certificate is issued from an independent Calibration Laboratory.

Two 10mil values, one on each edge of the comb

Can be used in accordance with:
ASTM D 4414-A, AS/NZS 1580.107.3, BS 3900-C5-7B, ISO 2808-1A, ISO 2808-7B, JIS K 5600-1-7, NF T30-125,
US NAVY PPI 63101-000, US NAVY NSI 009-32


Standards in grey have been superseded but are still recognised in some industries

Set of 4 Wet Film Combs
Terms & Conditions | Privacy Policy | Anti-Bribery Policy | ISO Certifications | Environmental Policies | Press | Sitemap | Copyright | © Elcometer Limited 2013