The Elcometer 456 Duct Deposit Measuring System has been specifically designed to meet the requirements of the DTT (Deposit Thickness Test) in HVCA’s (Heating & Ventilation Contractor’s Association) Guide to Good Practice, for the measurement of dust and grease deposits within ventilation systems and kitchen ducts made of ferrous metals.
By using the Elcometer 456 Ferrous Top Gauge with the specially designed probe and duct cleaning templates, readings can be taken of the deposit thickness on a specific test area, before and after cleaning.
ElcoMaster® software, supplied as standard with the Elcometer 456 Duct Deposit Measuring System includes a template designed specifically for reporting duct deposit measurements.
Part Number | Description |
A456CDUCT |
Elcometer 456 Duct Deposit Measuring System |
Measurement Range |
0 - 1500μm (0 - 60mils) |
Packing List |
Elcometer 456 Top Separate Gauge, Ferrous duct probe, duct cleaning template, Precision Foil Set 25μm, 50μm, 125μm, 250μm, 500μm, 1000μm, 2mm (x2), ElcoMaster® software, batteries, wrist harness, carry case and operating instructions |
T456CF2B |
Elcometer 456 Duct Probe |
T9913939 |
Duct Cleaning Template |
T99022255-8 |
Precision Foil Set: Scale 2B; 0 - 5mm (0 - 200mils) |
T99022255-8C |
Certified Precision Foil Set: Scale 2B; 0 - 5mm (0 - 200mils) |
T99913969 |
Ferrous Zero Plate |
T99920130 |
USB Bluetooth® Transmitter/Receiver |