Elcometer 500 Coatings on Concrete Inspection Kit

Non-destructive measurement of dry film thickness is now more accurate, faster and much easier on concrete than ever before, thanks to the new Elcometer 500 Coatings on Concrete Inspection Kit.

Housed in a sturdy, protective carry case and containing all the equipment required for on-site inspection of coatings on concrete and other similar substrates.

Supplied with both C1 & C2 probes, the Coatings on Concrete Inspection Kit allows the inspector to measure up to 10mm (390mils) on cemtitious substrates. 

The Elcometer 500 Concrete Coating Thickness Gauge can also measure film thickness on substrates including plasterboard, drywall, concrete block, brick etc. without damaging the coating.

The coating material library feature simplifies the coating inspection process; there is no need to set up gates, range values or known thickness of the coating. Just select the coating material from the gauge library and start measuring.

 

Key Features of the Elcometer 500 Coatings on Concrete Inspection Kit:

  • Accuratley measure up to 10mm (390mils) of dry film on cementitious substrates
  • Take more than 60 readings per minute in standard mode and over 140 readings in scan mode
  • Store up to 100,000 readings in up to 1,000 alpha-numeric batches
  • Bluetooth® & USB data output to PC and Android™ or iOS mobile devices

 

The Elcometer 500 Coatings on Concrete Inspection Kit includes:

 

  • Elcometer 500 Model T Coating Thickness Gauge
  • C1 Coating Thickness Probe; 0.15 - 2.5mm (6 - 98mils)
  • C2 Coating Thickness Probe; 0.75 -10mm (30 - 390mils)
  • C1/C2 Probe Measurement Foils: 1, 2, 3 & 8mm (40, 80, 120 & 310mils)
  • Elcometer 456 Ferrous Basic Integral Coating Thickness Gauge†
  • Elcometer 456 Calibration Foils:  0.5 & 1.5mm (20 & 60mils)†
  • Two Elcometer 500 Coating Calibration Moulds (unfilled)
  • Ultrasonic Couplant; 120ml (4fl oz) Bottle
  • Probe Tip Oil; 4ml (0.14fl oz) Bottle
  • ElcoMaster® Software & USB Cable

 

 

 

† A version of the kit without the Elcometer 456 is also available

Elcometer 500 Coatings on Concrete Inspection Kit
Elcometer 500 Concrete Coating Thickness GaugeElcometer 500 Concrete Coating Thickness GaugeCoating Calibration Mould (CCM)

Technical Specification

Part Number Description Certificate
A500-KIT1 Elcometer 500 Coatings on Concrete Inspection Kit
Packing List Elcometer 500 Model T Coating Thickness Gauge, C1 & C2 coating thickness probes, C1 & C2 probe measurement foils: 1, 2, 3 & 8mm (40, 80, 120 & 310mils), Elcometer 456 Model B Ferrous Integral Gauge, Elcometer 456 calibration foils: 0.5 & 1.5mm (20 & 60mils), 2 x coating calibration moulds, 2 x Wrist Harness, 6 x Screen Protector, 120ml (4fl oz) bottle of ultrasonic couplant, 4ml (0.14fl oz) bottle of probe tip oil, transit case, ElcoMaster® software & USB cable 

 

STANDARDS:
ASTM D6132, SSPC PA9 & ISO 2808 Method 10


Test certificate supplied as standard

 

Elcometer 500 Concrete Coating Thickness Gauge
Technical Specification

Elcometer 456 Coating Thickness Gauge
Technical Specification


 

Accessories

Part Number Description  
T50027602-1 C1 Replacement Probe Tip; Pack of 2 Intelligent Ergonomic C1 probe with replacement tip

T50027602-2

C2 Replacement Probe Tip; Pack of 2 Intelligent ergonomic C2 probe with replaceable tip
T50027604 Probe Tip Oil; 4ml (0.14fl oz) Bottle  
 

 

 

 

 
T92015701

Ultrasonic Couplant; 120ml (4fl oz)

 

T92024034-7

Ultrasonic Couplant; 300ml (10fl oz)  

T92024034-8

Ultrasonic Couplant; 500ml (17fl oz)  
T92024034-3  Ultrasonic Couplant; 3.8l (1 US Gallon)  
T92024034-9  Ultrasonic Couplant (High Temp); 60ml (2fl oz); for use in high temperature environments up to 510°C (950°F)  
     
T99022255-13  

C1 Foil Set: 1 & 2mm (40 & 80mils)

 

T99022255-13C

C1 Foil Set - Certified: 1 & 2mm (40 & 80mils)  

T99022255-14

C2 Foil Set: 3 & 8mm (120 & 310mils)  

T99022255-14C

C2 Foil Set - Certified: 3 & 8mm (120 & 310mils)  
     
T50027567-1 Elcometer 500 Coating Calibration Mould (CCM)  

 

How to create a coating sample using the Elcometer 500 Coating Calibration Mould (CCM)

 

The Elcometer CCM consists of a steel mould which has a sample and overflow chamber, together
with a clear plastic scraper The Coating Calibration Mould being used to create a coating sample The ferrous coating thickness gauge measuring the dry thickness of the substrate The dry film thickness measurement being saved into the Elcometer 500's Coating Material library
1. Place the coating calibration mould on a flat surface and completely fill the sample chamber with test coating. 2. Using the plastic scraper, scrape over the coating allowing the excess to fall into the overflow chamber. Allow the coating to dry.   3. When fully cured, calibrate a ferrous coating thickness gauge on the side of the CCM then measure and record the dry thickness at the centre of the coating.

4. Measure the same point using the Elcometer 500.


Enter the dry film thickness measurement and save it in the Elcometer 500's Coating Materials list.

Videos

How to Measure Coatings on Concrete using the Elcometer 500 Coating Thickness Gauge

The Elcometer 500 Coating Thickness Gauge incorporates state of the art electronics and measurement technology to accurately, repeatably and reliably measure up to 10mm (390mils) of coatings on concrete, or other similar substrates.

With a measurement rate of 60 readings per minute in standard mode, and more than 140 readings per minute in scan mode - the Elcometer 500 Coating Thickness Gauge can significantly reduce your inspection times.

 Click here to download the video in script in English.

 

RELATED VIDEOS

<P>How to Measure Coatings on Concrete using the Elcometer 500 Coating Thickness Gauge</P>

How to Measure Coatings on Concrete using the Elcometer 500 Coating Thickness Gauge

The Elcometer 500 Coating Thickness Gauge incorporates state of the art electronics and measurement technology to accurately, repeatably and reliably measure up to 10mm (390mils) of coatings on concrete, or other similar substrates.

With a measurement rate of 60 readings per minute in standard mode, and more than 140 readings per minute in scan mode - the Elcometer 500 Coating Thickness Gauge can significantly reduce your inspection times.

 Click here to download the video in script in English.

 

//www.youtube.com/embed/08SCWayyC5U?&showinfo=0
<P>How to Calibrate the Elcometer 500 Coating Thickness Gauge </P>

How to Calibrate the Elcometer 500 Coating Thickness Gauge 

The Elcometer 500 Coating Thickness Gauge incorporates state of the art electronics and measurement technology to accurately, repeatably and reliably measure up to 10mm (390mils) of coatings on concrete, or other similar substrates.
 
With a measurement rate of 60 readings per minute in standard mode, and more than 140 readings per minute in scan mode - the Elcometer 500 Coating Thickness Gauge can significantly reduce your inspection times.

 

Click here to download the video script in English.

 

 

 

https://www.youtube.com/embed/8A3JVbpMQdc?&showinfo=0
How to create a coating thickness sample for the Elcometer 500 using the Elcometer Coating Calibration Mould (CCM):
How to create a coating thickness sample for the Elcometer 500 using the Elcometer Coating Calibration Mould (CCM):

To obtain the greatest measurement accuracy, the Elcometer 500 can be calibrated using a known thickness of the coating to be measured.  If a sample of known thickness is not available, the Elcometer 500 Coating Calibration Mould (CCM) can be used to create a coating of known thickness which is traceable to both national and international standards.

 

Click here to download the video in script in English.

 

//www.youtube.com/embed/OQBQBGz41Es?&showinfo=0